Ventilation strategies for ARDS includes PEEP, tidal volume, and plateau pressure.
- Use low tidal volume, use 4 to 8 cc/kg ideal body weight. Target 6 cc/kg
- make sure to measure patients as females under report their height and males overreport
- Target plateau pressure < 30 cm H2O
- Use PEEP table
Using high PEEP and initial 6 cc/kg tidal volume can cause elevated plateau pressure. If plateau pressure is above 30 with initial setting, first check to make sure there is no ventilator desynchrony that could be minimized by increasing sedation. Next decrease tidal volume to 5 and then 4 cc/kg. Decreasing TV can cause more respiratory acidosis that could be offset by increasing respiratory rate or sodium bicarb.
Lecture Material
- women under report their height and can thus be over ventilated
Plateau Pressure
PEEP